MANUALIMPAC PyrometerISR 320
ISR 320 Manual Introduction 10OpticsSighting:Built-in LEDtargeting light andLEDs for intensity alignmentOptics: Fixed optics a=300 mm or a=800 mmDi
ISR 320 Manual Introduction 112.4 Dimensions2.5 Physical User Interface2.6 Accessories (optional)Numerous accessories guarantee easy installation o
ISR 320 Manual Introduction 122.6.3 Air PurgeThe air purge protects the lens from contamination of dust andmoisture. It has to be supplied with dry
ISR 320 Manual Controls and Installation 133 Controls and Installation3.1 Electrical InstallationThe pyrometer is powered by 24 V DC ± 25% (very we
ISR 320 Manual Controls and Installation 143.1.2 Connecting the pyrometer to a PCThe pyrometer is equipped with an RS485 serial interface. With the
ISR 320 Manual Controls and Installation 15can also be connected with its serial interface, whereas the digital display DA 6000-N has to beconnecte
ISR 320 Manual Controls and Installation 163.3 Optics3.3.1 Spot SizesThe ISR 320 has fixed optics for 300 mm or 800 mm measuring distance.The table
ISR 320 Manual Settings / parameter descriptions 174 Settings / parameter descriptionsThe pyrometer is equipped with a wide range of settings for o
ISR 320 Manual Settings / parameter descriptions 18Note: Emissivity Slope K Settings: 0.800 to 1.250 in steps of 1/1000 (2-color mode).4.2.1 Temper
ISR 320 Manual Settings / parameter descriptions 194.3 Transmittance Transmittance is a parameter that can compensate for signal loss due to exter
Confidential InformationThe material contained herein consists of information that is the property of LumaSenseTechnologies and intended solely for us
ISR 320 Manual Settings / parameter descriptions 20Double StorageMode:Double storage mode comes into effect when selecting one of the resetinterval
ISR 320 Manual Settings / parameter descriptions 214.7 Relative Signal StrengthRelative signal strength stands for the product of emissivity, surfa
ISR 320 Manual Settings / parameter descriptions 224.11 Sub RangeYou have the opportunity to choose a sub range (minimum span 50 °C) within the bas
ISR 320 Manual Settings / parameter descriptions 23Close below:The contact closes (switches to ground), if the temperature falls below theentered v
ISR 320 Manual Settings / parameter descriptions 24To ensure consistent document formatting, this page was intentionally left blank.
ISR 320 Manual Software InfraWin 255 Software InfraWinThe operating and analyzing InfraWin software is included with delivery of the pyrometer. Ina
ISR 320 Manual Software InfraWin 265.4 Basic settingsAll preset values for thedevice can be displayed andmodified, if necessary under theDevices/Pa
ISR 320 Manual Software InfraWin 27In the lower part of the window, the connection with the preset baud rate can be checked. Herethe command was se
ISR 320 Manual Software InfraWin 285.6 Warning Level / Switch-Off LevelIn addition to the relative signal bar graph, the warning level and the swit
ISR 320 Manual Software InfraWin 29Once the temperature entry has beenentered and confirmed with OK,InfraWin will then calculate theemissivity slop
ISR 320 Manual Contents iiiContents1 General Information ...
ISR 320 Manual Software InfraWin 30frequency that readings were taken (settings at 5.9 PC sampling rates). As the amount of dataincreases, so does
ISR 320 Manual Software InfraWin 31After entering the aperture and the main spot size, the input of interim values calculates spotsizes in differen
ISR 320 Manual Software InfraWin 32To ensure consistent document formatting, this page was intentionally left blank.
ISR 320 Manual Data format UPP 336 Maintenance6.1 Cleaning ISR 320 windowBecause there are no moving parts in the ISR 320, the only regular mainten
ISR 320 Manual Data format UPP 34In the 1-color (mono) mode, the pyrometer can measure objects at any distance.However, the object has to be bigger
ISR 320 Manual Data format UPP 357 Data format UPP (Universal PyrometerProtocol)Software commands can be exchanged directly with the pyrometer thro
ISR 320 Manual Data format UPP 36Description Command ParametersMeasuring value(one-channel andratio temperature)AAek Answer: SSSSSQQQQQ2x5 decimal
ISR 320 Manual Data format UPP 37Description Command ParametersMeasuring value AAms Answer: QQQQQ (88880=Overflow)5 decimal digit (in °C or °F, la
ISR 320 Manual Data format UPP 38To ensure consistent document formatting, this page was intentionally left blank.
ISR 320 Manual Reference Numbers 398 Reference Numbers8.1 Reference numbers instrumentTemperature Range Reference Number a / mmISR 320, 700 to 1700
ISR 320 Manual Contents iv4.4 Response Time (t90) ...
ISR 320 Manual Reference Numbers 403 852 290Power supply NG DC for DIN rail mounting; 100 to 240 V AC 24 V DC, 1 A3 852 550Power supply NG 2D for
ISR 320 Manual Troubleshooting 419 TroubleshootingSymptom Probable Cause CommentsNo analog output even if thedisplay shows a temperatureabove lower
ISR 320 Manual Troubleshooting 42Symptom Probable Cause CommentsIncorrect slope adjustments. See sections 4.2, 5The measurement is influenced by re
ISR 320 Manual Troubleshooting 43Symptom Probable Cause CommentsNoisy readings (fastfluctuations).Improper grounding of cable shield and/orISR 320
ISR 320 Manual Troubleshooting 44To ensure consistent document formatting, this page was intentionally left blank.
ISR 320 Manual Index 45Index11 measure… 26AAccesories 11Air Purge 12Analog Output 20Appropriate use 9BBasic settings 26Baud Rate 22CCalibration 33L
ISR 320 Manual 46SSafety vScaling Trend button 29Scope of delivery 9Service Request 6Settings / parameter descriptions 17Sighting 15Single Storage
ISR 320 Manual Contents v1 General Information1.1 Information about the user manualCongratulations on choosing the high quality and highly efficien
ISR 320 Manual General Information 61.3 Limit of liability and warrantyAll general information and notes for handling, maintenance and cleaning of
ISR 320 Manual General Information 7Technical Support can be contacted by telephone or email:Santa Clara, California Telephone: +1 408 727 1600 or
ISR 320 Manual General Information 8To ensure consistent document formatting, this page was intentionally left blank.
ISR 320 Manual Introduction 92 Introduction2.1 Appropriate useThe IMPAC ISR 320 pyrometer is a stationary, digital pyrometer for non-contact temper